問い合わせ
問い合わせ 在庫確認

What would cause the reed contacts to open and close, after a while, using a high carry current?

Currie Temperature.  The reed contacts become so hot that they reach the currie temperature of the nickel/iron material.  At the currie temperature the materials lose their ferromeagnetic properties.

カテゴリー:

ニュースレターの申し込み

We Will Use The Email Address You Provide To Send You Marketing And Promotional Materials.

展示会&イベント

APEC 2022 – Applied Power Electronics Conference & Exposition
Booth No.: 802
For More Details, Click Here.

Follow Us

Focused. Leadership

Video
ダウンロード
Products compare