Contact Us
Contact Us Stock Check

Optocouplers |

Optocouplers are intrinsically safe circuits that handle input/output isolation as high as 4,000 volts DC. Many of our optocouplers have met and been certified for the stringent requirements of ATEX and IECEx. Hence an optocoupler will not become an ignition point when subjected to short circuits or adjacent component failures. Furthermore they must also switch to a defined state when overloaded. Hazardous environments include any environment where an electrical arc could spark or ignite an explosion. Such as petrol-chemical, grain and medical processing plants. Additionally these optocoupler series offer long life due to non-abrasive mechanical wear and high reliability. And insulation resistance between input and output up to 10^13 ohms. Contact our experts for assistance with your optocoupler designs.

Parametric Search

522 Series Optocouplers

Miniature 522 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, CTR min. 0.5, cutoff 85kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^12 Ω. Distance between input and output for highest safety requirements up to 12mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 522 Optocoupler Series


 

525 Series Optocouplers

525 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, CTR min. 0.5, cutoff 50kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^12 Ω. Distance between input and output for highest safety requirements up to 14.5mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 525 Optocoupler Series


 

535 Series Optocouplers

535 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, CTR min. 3.0, cutoff 2kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^13 Ω. Distance between input and output for highest safety requirements up to 14.5mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 535 Optocoupler Series


 

567 Series Optocouplers

567 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, cutoff 500kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^13 Ω. Distance between input and output for highest safety requirements up to 14mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 567 Optocoupler Series


 

521 Series Optocouplers

521 Series Optocouplers for the galvanic separation of intrinsic safety circuits, Isolation voltage min. 6kVDC, CTR min. 0.5, cutoff 50kHZ. Insulation resistance input /output up to 10^13 Ω. Distance between input and output for highest safety requirements up to 24.5mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.

528 Series Optocouplers

528 Series Optocouplers for the galvanic separation of intrinsic safety circuits, Isolation voltage min. 10kVDC, CTR min. 0.9, cutoff 50kHZ. Insulation resistance input /output up to 10^12 Ω. Distance between input and output for highest safety requirements up to 42mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.

Optocoupler 530-03

530-03 Series Optocouplers for the galvanic separation of intrinsic safety circuits, Isolation voltage up to 20kVDC, CTR min. 0.5 (50%), cutoff 50kHZ. Insulation resistance input /output up to 10^12 Ω. Distance between input and output for highest safety requirements min. 34mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.

Optocoupler 530-70

530-70 Series Optocouplers for the galvanic separation of intrinsic safety circuits, Isolation voltage min. 22kVDC, CTR min. 0.8%, cutoff 100kHZ. Insulation resistance input /output up to 10^12 Ω. Distance between input and output for highest safety requirements min. 39mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.

Load more

ATEX & IECEx certified

522 Series Optocouplers

Miniature 522 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, CTR min. 0.5, cutoff 85kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^12 Ω. Distance between input and output for highest safety requirements up to 12mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 522 Optocoupler Series


 

525 Series Optocouplers

525 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, CTR min. 0.5, cutoff 50kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^12 Ω. Distance between input and output for highest safety requirements up to 14.5mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 525 Optocoupler Series


 

535 Series Optocouplers

535 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, CTR min. 3.0, cutoff 2kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^13 Ω. Distance between input and output for highest safety requirements up to 14.5mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 535 Optocoupler Series


 

567 Series Optocouplers

567 Series Optocouplers for the galvanic separation of intrinsic safety (EXi) circuits, Isolation voltage min. 4kVDC, cutoff 500kHZ, ATEX & IECEx Certified (18 ATEX 0017 U, KIWA 18.009 U). Insulation resistance input /output up to 10^13 Ω. Distance between input and output for highest safety requirements up to 14mm. Galvanic separation and minor coupling capacitance between input and output circuit. Analog & digital signal transfer is possible. Minor output delay times compared to relays. Long life due to non mechanical wear. Magnetic fields do not impact operation. A photo-diode makes for very short cycle times. Able to invert the output signal during transfer.


Type of protection: II (1) G [Ex ia Ga] II C
In accordance with: EN 60079-0, EN 60079-11

ATEX Examination Certificate & Assessment Report

IECEx Certificate of Conformity

Mounting Instructions for 567 Optocoupler Series


 