Contact Us
Contact Us Stock Check

Why would a HV reed relay pass testing then after sitting for days fail during retest?

In relays which have two switches in series:  If one of the switches loses its vacuum, it will have a low breakdown voltage.  Two switches in series is used to achieve the additive effect of two 10,000 volt breakdowns adding to give over 20kV.  So what has probably gone wrong is one of the switches has lost its vacuum, perhaps due to a small crack or a bad seal.  Try to remove some of the epoxy on the end were the reeds are soldered together and then test them individually to see which one may be bad.

Posted in

SUBSCRIBE TO OUR NEWSLETTER

We Will Use The Email Address You Provide To Send You Marketing And Promotional Materials.

  • This field is hidden when viewing the form

Tradeshows & Events

APEC 2025 – Applied Power Electronics Conference & Exposition
Time: March 16-20, 2025
Place: Georgia World Congress Center in Atlanta, Georgia
Booth No.: 1717
For More Details, Click Here.

Follow Us

Focused. Leadership

Video
Download Table
Products compare