Typically we indicate the reed contacts open within 50 microseconds. However, this does not mean that you can immediately apply a voltage across, particularly if you are working with high voltages. Breakdown voltage or dielectric strength is stipulated for a given AT range (mT range). For high voltages we use the highest range that will work for a given set of pull-in voltage requirements. With that said, when the contacts first open they will waiver for at least a few milliseconds. During this time the contacts will come close to closing in a periodic manner. During these close encounters the dielectric strength will be much reduced. If this is a consideration in a customer circuit, care must be taken to wait a sufficient amount of time before re-applying the high voltage.
This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.