联系我们
联系我们 库存

继电器

干簧继电器一边测量5KV,另一边测量几百伏正常吗?

Whenever you make a voltage measurement, one must consider the effect of creating a voltage divider.  What is the resistance on the other side of the switch?  For instance, if the switch measures 1E10 ohms and it is connected to a 100 mega ohm (1E8) resistor and 10,000 volts is applied to the other end of the switch away from the resistor, and series circuit is set up such that some of the voltage will be dropped across the switch and some will be dropped across the 100 mega ohm resistor.  One has a series circuit set up with basically two resistors in series. One resistor is the switch at 1E10 ohms and the other the load resistor 1E8 ohms.   When applying 10,000 volts to this circuit approximately 1 µA of current will flow to the open switch and through the load resistor.  Simply using ohms law the 1 µA will generate 100 volts across across the load resistor.  Now if the insulation resistance across the switch is 1E11 ohms the voltage across the resistor would only be 10 volts.  However, if the insulation resistance across the reed switch is 1E9 ohms, then the voltage across the load would be up to 1000 volts.I hope this all makes sense to you.  Obviously, the insulation resistance across the reed switch is very important as is load resistance.  Hope this explains better what you and the customer are seeing.

低热干簧继电中使用哪种热芯片?

Generally thermal compensation is required in a low thermal relay.  Alumina and Beryllia are commonly used because they have great thermal conductivity while they maintain electrical isolation.

Is thermal offset voltage produced by the reed switch connected to copper from a thermocouple within the relay?

For a low thermal reed relay at 20°C the reed switch junction connected to copper will generate 1 millivolt and changing the junction by 1°C will generate an additional 60µV.

磁场是否有助于低热干簧继电器的生成?

The higher the coil resistance the less power produced by the relay and therefore there will be less thermal offset voltages generated.  By applying a magnetic shield, the contacts see a much stronger magnetic field.  This allows the relay designer to increase the coil resistance which in turn reduces relay power and heat generation.

高线圈电阻有助于低热,低补偿电压干簧继电器的生成吗?

Yes, the coil resistance directly controls the amount of heat generated in the relay. The more heat generated, the more the need to compensate for thermal voltage offsets.  Making the coil resistance as high as possible is a clear step in the right direction.

如何制作低热继电器?

A reed switch is made up of nickel/iron and when connected to copper (a PCB trace), you end up with a thermocouple producing a high offset voltage. Since you have this thermocouple on each end, you need to compensate for these high offset voltages, otherwise they will swamp out any small offset signals the customer is trying to switch.  So the key to make a low thermal relay is to develop a compensation technique that will compensate for these high offset voltages.  Carefully placed thermal chips get the job done.

低热继电器中使用哪些切换配置?

Generally low thermal relays switch differential signals that require two single throw relays.  A one pole single throw relay is used on the front end of high end multimeters.

低热干簧继电器的应用领域有哪些?

Low thermal or low offset reed relays are used in applications where transducers are used that produce very low voltage signals that need to be switched and amplified. They are also used on the front end of high end multimeters and switching thermocouples in data acquisition systems.

什么是低热干簧继电器?

低热干簧继电器用于在低微妙 (µV) 范围内切换低电压,且信号在穿过继电器后不发生任何改变。

SIL和MS系列产品可在多高射频下使用?

SIL 系列产品可在频率高达800MHz下使用,MS 系列产品可高达 1.5 GHz。

如果继电器没有屏蔽,是否能将它们作为射频继电器使用?

Yes, a simple trick which improves the RF characteristics of a relay is to ground the start wire of the coil.  Since the coil wire is copper, its first layer can represent the shield for the signal.  This may allow the customer, using this technique to switch and carry RF signals up to 500 MHz.  This allows us to use the SIL and MS relay series in RF circuits.

如何确保我的射频测试结果与工厂相关联?

最佳的方式就是使用相同的测试夹具进行射频测试。我们可以将射频测试夹具借给客户使用从而获取相同的结果。

客户如何将我们的射频继电器与自己的PCB相匹配?

Once our customers receive our RF surface mount relays they need to match the impedance going in and coming out of our relays to his PCB.  They do this by adding small amounts of capacitance and/or inductance on each side of the relay at the junction of the relay and the PCB.

在射频电路中,切换配置”T” 指什么?

A ‘T’ switching configuration is a way to improve isolation in RF circuits.  It comprises three reed relays.  The relays are arranged in the following manner: one is on the left upper part of a T, the second one in on right side of the T after the junction, and the third relay is mounted on the vertical component of the T.  For maximum isolation, the first and second relays are in the open state. The third relay is closed and its bottom end of the T is grounded.  With the first relay open any signal that leaks thru to the junction of the three relays will be shunted to ground.  Any signal still left at the junction will be further isolated by the open contacts of the second relay.  When conducting a signal through the ‘T’, both the first and second relay are closed allowing the signal path.  The third relay is open.  The ‘T’ configuration will improve isolation, but there will be some signal loss due to the longer signal path.

为了产生最佳性能,射频干簧继电器在PCB上的贴装方式是什么?

Our customers should mount our RF reed relays in a surface mount environment assuming he has chosen one of our surface mount reed relays.  For best performance, he should mount our relay axially on his PCB.  Also, he needs to tune his impedance on his PCB to exactly match ours going into and out of our relay.

射频继电器贴装在PCB板上的最佳方式是什么?

To get the best RF performance from a reed relay, its leads should be mounted axially to the PCB.  This means that a hole needs to be cut in the PCB for almost half of the relay body to sit in.  Here the leads exit the reed relay in a straight line with no turns minimizing signal travel.

如何制作最佳射频干簧继电器?

为了制作最佳射频干簧继电器,你需要制作一个简单的几何设计,尽量简短,最好是最小限度改动的同轴设计。

为了提高射频特性,在一个指定继电器封装内放置多个继电器有用吗?

If your customer is using multiple relays in a matrix format and is passing RF signals through the matrix it makes good sense to offer them a multiple relay matrix in the same package. This is particularly true when the relays are in series, because this essentially reduces the signal path length. In this case, the path length in and out of the relays is eliminated, where the signal simply travels out of one relay and into another relay with minimal path distance.

射频干簧继电器的路径长度是否影响其特性?

Yes, always strive for the shortest path length the signal will see, going through the reed relay.  Also, minimize the number of turns the signal needs to take, going through the reed relay.

更好地控制特性阻抗能否提高干簧继电器的射频特性?

Yes, the more consistent the characteristic impedance and the closer to 50 Ω, the better the RF characteristics.  Whenever there is the slightest change in impedance, some of the signal will be reflected reducing the insertion loss.

如何对干簧继电器做射频测试?

测试干簧继电器的射频特性并不是个简单的事情。你需要一个带射频测试夹具的网络分析仪  See the Standex Electronics Engineering Note: Testing of RF switching components.

如何控制和提高干簧继电器的绝缘度?

The isolation for a reed relay in an RF circuit is basically determined by the gap distance.  So the only way to control or improve the isolation in the reed relay design is by going to a wider gap reed switch.  This means using a higher ampere turn switch which translates to a higher powered coil.

S参数如何生成?

S-parameters are generated by our network analyzer when we make RF measurements.  Since they are stored electronically, they can easily be passed along to RF designers and potential customers via email.

如何使用S参数?

The S – parameters are important to the designer of an RF circuit because they are used by placing them in RF software.  This software simulates an RF circuit. In this way, the RF designer has an idea of how our relay will interact with other RF components, in their circuit.

当干簧管为圆形时,如何计算干簧继电器的特性阻抗?

A reed relay designed to carry high frequencies will generally use a coaxial design approach.  With this in mind the formula to calculate the characteristic impedance  is the following: Z = 60/(√(€R) + ln(2h/d)) where Z is the characteristic impedance, √  is the square root, (€R)  is the dielectric constant between the shield and the reed switch, ln – is the natural log, h is diameter of the shield, d is the diameter of the reed switch.

当干簧管为扁平时,如何计算干簧继电器的特性阻抗?

A reed relay designed to carry high frequencies will generally use a coaxial design approach.  With this in mind the formula to calculate the characteristic impedance is the following: Z = 60/(√(e)) ln((D)/A) where Z is the characteristic impedance, √(e) is the square root of the dielectric constant, ln – is the natural logarithm, D is the diameter of the shield, and A is the cross sectional of the reed blade.

射频电路中如何计算电感?

电感是使用以下公式计算:L = µo n d A1 。其中L是电感,μ0是磁导率常数,n表示匝数,d为信号线的长度,A 1是信号线屏蔽的长度。

射频电路中如何计算电容?

电容计算公式如下:C =( e A)/d。其中C是电容,e是绝缘常数,A是屏蔽和干簧开关舌片,d是屏蔽层和舌片之间的距离。

如何计算阻抗特性?

阻抗特性是通过以下公式计算:Z =√(R +(XL – XC)2),其中Z是阻抗特性,R是直流电阻,XL是感抗,Xc是容抗。

如何计算容抗?

容抗计算公式如下:XC= 1 /(2ΠfC),其中XC为以欧姆为单位的容抗,f是以Hz为单位的频率,C是电容。

如何计算感抗?

感抗由下列公式计算:XL=2πFL,其中XL是以ohms为单位的感抗,f是单位为Hz的频率,L是电感。

在指定信号路径上,什么导致阻抗特性更改?

在信号路径上指定点上,如果电容,电阻或者电感发生改变,阻抗特性也会改变。

在指定信号路径上如果阻抗特性改变会发生什么?

当一个脉冲在指定的信号路径上遇到阻抗特性变化,它的部分信号强度将被反射回沿原信号路径,这代表了信号强度的损失。

射频中阻抗特性由什么组成?

阻抗特性由以下主要成份组成:信号路径,屏蔽,以及与其相应的绝缘常数。

如何控制阻抗特性?

The signal path and its length is critical.  The shorter the better.  It’s best to think of the signal path and the shield as a geometric shape.  Maintaining that geometric path as consistent as possible is critical.  Any variation will change the characteristic impedance and will produce signal loss.

当数字脉冲经过一个指定电路,通过每个元件时信号强度会丢失吗?

If a given relay has rise time of 50 picoseconds, a given digital pulse passing through it will have its rise time increased by 50 picoseconds.  Now, if they have to travel through a matrix of five relays, its rise time will increase by 250 picoseconds.  Now the frequency response after one relay is 20 GHz but after the fifth relay it is down to 4 GHz.  So it’s important for the system designer to know how many relays or components its signals will pass through to determine if the components will work in his circuit.

数字时钟运行频率2GHz与连续波射频如何比较?

To equate continuous wave with a digital clock running at 2 GHz, you have to consider how many harmonics of the base frequency are needed to construct the digital pulse.  Normally at least 5 harmonics of the original frequency need to be considered.  So for 2 GHz this represents a continuous wave frequency of 10 GHz.  So to pass 2 GHz digital pulses in a circuit it would need to have a frequency response of 10 GHz.

为什么快速数字脉冲被认为射频?

The critical area of a digital pulse is its rise time. If the rise time of the pulse’s leading edge is for instance 50 picoseconds, the corresponding frequency is equivalent to 20 GHz.

S参数是什么?

S – parameters are supplied for a given frequency and are supplied with a magnitude and direction.  They are very useful in supplying information about the characteristics of a component in digital format.   They can also allow the RF designer to know how that component will function in his circuit, before the actual component is added to the circuit.

射频电路中转换速度是指什么?

When you pass a digital pulse through a component or a circuit it will enter the circuit with a certain rise time.  When it leaves the circuit or component it will have a new rise time.  The slew rate is the difference in rise times from the leaving rise time minus the arriving rise time.

射频中上升时间是指什么?

Rise time is usually referred to in digital circuits.  The shorter the pulses the more important the rise time has become.  It is measured as the time from the beginning of a pulse to the 90% point of the pulse height.  Circuits need to be able to have good RF characteristics to pass these fast pulses. Rise time is an important parameter that needs to be accounted for.  Circuits not capable of handling fast rise time pulses would effectively swamp out the digital pulses.

VSWR是指什么?

VSWR stands for voltage standing wave ratio.  When signal traveling in a circuit are reflected back, they may reach another component and then be reflected forward again.  These reflections back and forth can produce standing waves in the circuit.  These waves can create a very lossy circuit.

什么是回波损耗?

当一个信号进入一个电路或元件,某些信号可能会被反射回它原来的方向。回波损耗是指信号损失的量度。

什么是插入损耗?

Insertion loss is the loss of signal when traveling in and out of a given circuit or traveling into a component and out of the component.  If your signal is at 100% going into a component, and coming out there is a loss, its described as insertion loss and is measured in decibels (dB).  3 dB is described as the end point for any component and is equivalent to the signal strength being reduced by 50%.

什么是射频绝缘度?

RF can and does cover over open circuits.  The amount of signal that travels from the input to the output of a switch represents that measure of isolation measured in decibels (dB), -65 dB is considered the best for isolation. Generally -20 dB is a workable level.

什么是阻抗特性?

RF like to travel within a circuit with a consistent characteristic impedance.  Any changes in characteristic impedance will produce signal loss.  Characteristic impedance Z is essentially a measure of resistance.  It has three components that are added vectorially. The components are: the pure DC resistance in the x- axis, the inductive reactance in the y-axis, and the capacitive reactance in the z-axis.  The characteristic resistance is calculatd all along a given signal path and any change in any one of the 3 above resistances at any point will alter the resistance.  50 ohms (Ω) is the most generally accepted resistance in most RF circuits.

切换射频与切换直流为什么不同?

RF rides on the outer part of the conductor.  The higher the frequencies, the farther it moves to the outer edge of the conductor.  Many RF characteristics are quite different than DC.  It has a whole new set of parameters:

  • characteristic impedance
  • insertion loss
  • VSWR
  • rise time
  • isolation
  • slew rate
  • etc.
使用干簧继电器切换射频的利弊是什么?

The reed relays have a flat frequency response out to 20 GHz.  Their cost is moderate and stable.  Their size is becoming smaller and smaller.  Quality issues has been their main problem.  They are not good at switching higher power, but improvements are under way in this area.

使用机械式继电器切换射频的利弊是什么?

Electromechanical relays can switch up to 20 GHz.  They can be very expensive and are very large.  Like the reed relay they do have a good flat frequency response.  Their large size takes up too much board space and they require a lot of power to operate. They have very good isolation and have the ability to switch higher power RF.

使用半导体切换射频的利弊是什么?

Semiconductors can be used to switch up to 100 GHz.  Cost becomes very high over 10 GHz.  Semiconductors represent the smallest size when compared to the other technologies.  Its frequency response has discontinuities.  They have inter modular distortion and need added circuitry to control.  They also need added circuitry to improve its frequency response.

为什么使用半导体开关干簧继电器或机械式继电器切换射频?

Reed relays are very linear over a large span of frequencies, typically ranging from DC up to 20 GHz.  Semiconductors need filters and suffer from inter modular distortion.  This means additional components need to be used.  The reed relay by itself will do the job and are ideal when switching low signal level RF loads.  The reed relay’s size is much smaller than the electromechanical relay and comparable in size to the semis.

使用什么元件来切换射频?

一般使用半导体,干簧继电器和机械式继电器来切换射频,各有利弊。

快速数字脉冲是射频吗?

RF are waves of electrical impulses that oscillate at very high frequencies.  The waves are no different than our 50 cycle or 60 cycle line voltages and currents.  Instead of having 50 or 60 cycles occurring every second you can have billions occurring every second.  A frequency of 1 GHz is a frequency that is oscillating at 1 billion times every second.  In the digital world electrical pulses pass along information.  The shorter the pulses the more one can pass added information every second.  A computer operating at 2 GHz is capable of processing 2 billion pulses every second.  For electronic circuits to process a pulse it has to have the ability to carry 5 times its base.  This means that the circuits carrying 2 GHz pulses need to have the capability of carrying 5 times that or 10 GHz on an RF basis.  This is because square waves are made of 5 harmonics of the original frequency.

什么是集肤效应?

RF energy (a combination of voltages and currents) when traveling through a conductor will tend to travel on the outer part of the conductor.  The higher the frequency, the more the RF energy is traveling on the outer diameter of the wire, or traveling on the ‘skin’ of the conductor.  This effectively reduces the cross sectional area in which the energy can travel.  If it is only signal level the RF energy will pass thru the conductor with a minimal amount of attenuation attributed to resistive loss.  However, if the RF energy is significant, where a fair amount of power is being conducted through the conductor. Severe resistive losses may occur.  Dramatic lose of signal may occur.  Furthermore, major heating may occur that could cause the temperature on the contacts to rise above the curie temperature.  In this case, the reed leads will lose their magnetism resulting in the contacts opening.  This now can cause complete destruction of the reed switch contacts.  This is produced by the contacts reclosing once its temperature drops below the curie temperature and its magnetic properties are regained.  Now the contacts will close the full load and heating will begin again until the curie temperature is reached again.  Here the contact will open and close until the contacts are shorted or destroyed.  In this case, adding copper to the outer surface of the contacts and their leads will reduce and or eliminate the potentially disastereous effects.

为什么高压继电器在1-2KV击穿前故障,显示低绝缘电阻?

检查磁簧开关,看看是否裂缝。如果没有,你应该将干簧管送回Standex Electronics并确认干簧管是否真空状态。

为什么高压干簧继电器测试通过后过了几天重新测试失败?

In relays which have two switches in series:  If one of the switches loses its vacuum, it will have a low breakdown voltage.  Two switches in series is used to achieve the additive effect of two 10,000 volt breakdowns adding to give over 20kV.  So what has probably gone wrong is one of the switches has lost its vacuum, perhaps due to a small crack or a bad seal.  Try to remove some of the epoxy on the end were the reeds are soldered together and then test them individually to see which one may be bad.

如果高压干簧继电器触点在测试过程中突然关闭怎么办?会导致人员触电吗?

If the high voltage is still testing good, it sounds to me like they may have switched too much power and/or carried too much current.  Carefully break open the reed switch capsule and look at the contacts to see if there is any sign of pitting or burn marks right on the end of the contacts where they come together when the contacts close.  If you see this, you will need to find out exactly what the customer is applying to the contacts and/or what he is carrying across the contacts. There are a few things that the customer can do:

  1. Add some series resistance in the direct line of the reed switch to reduce the max switching current.
  2. Check for any added cable or wire that adds stray capacitance.
  3. Make sure there are no common mode voltages present.
  4. Also, in his application, is it possible to switch the contacts dry (no voltage or current) for maximum life.  This may not be possible.
  5. If the customer is switching some capacitance, can they add some inductance in series?
射频和快速数字脉冲的区别是什么?

RF are waves of electrical impulses that oscillate at very high frequencies.  The waves are no different than our 50 cycle or 60 cycle line voltages and currents.  Instead of having 50 or 60 cycles occurring every second you can have billions occurring every second.  A frequency of 1 GHz is a frequency that is oscillating at 1 billion times every second.  In the digital world electrical pulses pass along information.  The shorter the pulses the more one can pass added information every second.  A computer operating at 2 GHz is capable of processing 2 billion pulses every second.  For electronic circuits to process a pulse it has to have the ability to carry 5 times its base.  This means that the circuits carrying 2 GHz pulses need to have the capability of carrying 5 times that or 10 GHz on an RF basis.  This is because square waves are made of 5 harmonics of the original frequency.

什么是射频干簧继电器?

An RF reed relay is specifically designed to carry high frequencies up to 20 GHz and carry digital pulses in the sub nanosecond pulse widths.  Shielding is critical and the geometry of the signal path as it relates to the shield is of utmost importance.  The higher the frequencies the more critical they become.

射频继电器的主要市场有哪些?

射频继电器通常用在PCB功能和集成电路测试设备上。它们也可以在医疗电子或者其他使用射频或快速数字脉冲的市场。

我们提供哪些射频干簧继电器?

•  高达500 MHz – 使用SIL 6pin和LP系列
•  高达1 GHz – MS(微SIL), 接地线启动
•  高达17 GHz – CRF高达7 GHz和SRF系列

高压ATE要求,高承载电流,我们需要使用什么系列继电器?

使用小型铜电镀密封干簧管的LI 或BE 系列继电器。

高压ATE要求需要使用什么系列继电器?

使用ORD2210V干簧管的SIL HV 或者 LI系列继电器。

医疗烧灼发动机需要使用什么系列继电器?

使用带高压铜电镀干簧触点且能承载高电流的HE 或HM 系列继电器。

集成电路VLSI测试仪(ATE)需要使用什么系列继电器?

根据数字脉冲熟读来决定使用CRF 或者SRF系列高频率干簧继电器。

PCB 功能测试仪(ATE)需要使用什么系列继电器?

根据大小/成本来决定使用SIL, MS 或者CRR 系列继电器。

高端电压表推荐使用什么系列继电器?

使用高压绝缘且能在小于1uV电压下切换的特殊BT 系列继电器。

手提式除颤器需要使用什么系列继电器?

使用2极特殊BE系列继电器。

当5kV高压到达15kV击穿电压,我们应该使用什么产品?

使用HE 和HM 系列干簧继电器。

当切换触点时,如果小于1uV 补偿电压不存在,我们需要使用什么继电器?

使用BT系列或者特殊BT低热干簧继电器。

低电流(ATE),频率高达8 GHz到20 GHz,需要用什么继电器?

请使用SRF系列干簧继电器。

低电流(ATE),频率高达1 GHz到7 GHz,需要用什么继电器?

请使用CRF 系列干簧继电器。

低电流(ATE),频率高达 500MHZ到1GHz ,需要用什么继电器(临界大小)?

请使用CRF系列或SRF系列继电器。

低电流(ATE),频率高达 500MHZ到1GHz ,需要用什么继电器(大小不重要)?

,接地线启动。请使用6 Pin SIL 系列或者MS系列接地线启动继电器。

最小封装,低电流,频率高达500MHz,需要用什么继电器?

请使用CRF或者SRF 系列继电器。

低电流,频率高达500MHz, 我需要使用什么继电器?

如果大小不限制,请使用SIL系列(6 pin)或MS系列(接地启动线圈引脚。

什么是共模电压?

All too often customers find their relays failing early in their life times that is often caused by the existence of common mode voltages.  Common mode voltages usually arise from line voltages in the area or nearby a given circuit.  If there is stray capacitance in the line it can become charged to the peak of the line voltage.  If the line voltage is 240 VRMS this translates to potential peaks as high as 400 volts.  Switching this voltage even though the stray capacitance is only, say, in the order of 50 picofarads, it will cause metal transfer on the contacts.  This will eventually cause early life failures.  Better grounding can eliminate common mode voltages.  Reducing the stray capacitance will help.  Also, adding some resistance in series with the contacts will reduce the inrush.  Keep in mind all the damage occurs in the first 50 nanosecond upon contact closure.

什么是多极继电器?

Reed relays can be constructed with more than one switch.  Standex Electronics typically will manufacture up to four reed switches in a given relay.  This could be up to 4 single pole normally open switches, up to 4 single pole normally closed switches, or up to 4 single pole double pole throw switches.

什么是封闭继电器?

A latching relay is bistable.  It can be in the closed state with no coil power applied or it can be in the open state with no coil power applied.  It only takes a pulse of 1.5 milliseconds to change from the open state to the closed state; or a 1.5 millisecond pulse will change from the closed state to the open state.  A magnet partially biases the reed switch to create the latching states.  Generally two coils are used: one is used for closing the contacts and the other is used for opening the contacts.

什么是1B干簧继电器?

With a Form B relay, the contacts are biased closed with a magnet.  So with no power on the coil, the contacts remain closed.  When power is applied to the coil, its magnetic field is opposite the field of the magnet, cancelling it out and opening the contacts.

什么是自动接入?

This is usually a condition that can develop when using a Form B or normally closed reed relay.  The contacts are biased closed with a magnet. So with no power on the coil, the contacts remain closed.  When power is applied to the coil, its magnetic field is opposite the field of the magnet cancelling it out and opening the contacts.  If the coil is too strong, the contacts can reclose.  So a reclose voltage is added to a Form B relay that is usually 25% to 50% above the nominal voltage.  For a 5 volt relay with 50% safety factor the reclose would be 7.5 Volts.  This guarantees to the customer that applying up to 7.5 Volts the contacts will not reclose.

什么是峰包功率?

This description is used in radio transmitter and RF applications.  The old radio designs used amplitude modulation.  The wave basically varies in size with the audio content, but is transmitted using a 30 MHz envelope.  So PEP is just an expression that expresses that in very abbreviated terms.  The audio is superimposed on the RF.  This is what AM music is/was  – audio modulation before digital modulation.

什么可能导致干簧继电器多次高吸合电压故障?

We suggest checking the following items:

  1. Are you using a metal cover?  If so, is it cold rolled steel?  Is it a ferromagnetic material?
  2. Are you using a bobbinless coil?  If so, is there enough room to make the I.D. a little smaller in diameter?
  3. What is the actual range of pull-in voltage?
  4. Is there enough room to do a 1/2″ wire size larger on the coil wire?
  5. Is the reed switch bent and formed? Or is it cut and soldered to a post?  If soldered to a post go to a nickel iron pin and weld the reed switch.
  6. If all of these fail consider using an internal magnetic shield in addition to the magnetically shielding cover.
哪款干簧产品满足高功率RF要求?

Best to use a small copper plated reed switch in an application where the carry current is about 3 amps RF.  Greater than 3 amps you should use a large copper plated reed switch.  The RF will be riding on the outside ‘skin’ of the switch.

击穿电压高达5000V,我需要选择哪款产品?

使用Standex Electronics KSK-1A85干簧管系列。

电流10-50毫安,切换5-15V , 我该选择哪款干簧产品?

使用ORD228,ORD211铱,或ORD311。

电流10-250毫安,切换15-35V , 我该选择哪款干簧产品?

For a sensor use the ORD228 with iridium or the ORD2210 for a relay.

低电压电流切换使用哪种干簧开关?

小型机电继电器不适合低电压和低电流切换。机电继电器需要强大的电压和/或电流来打破任何薄膜堆积。正是这种薄膜堆积不允许极低的电压和电流通过触点。干簧开关显然是最佳的解决方案。使用镀钌触点或铱触点是这些低电负载的最佳材料。

什么时候使用真空干簧开关?

切换和击穿电压达到250V及以上最佳使用真空干簧开关。在电流不太高的情况下,ORD2210V可以有效地达到4000V。电压高于4000V时,建议使用密封干簧开关。

施加多少电压干簧管会打开?

Miniature reed switches less than 20 mm (0.80 inches) glass length can effectively break up to 250 Volts.  This depends on the pull-in AT (mT) used.  The higher the better.  Reed switches less than 10 mm will shrink this value to around 150 volts.  Minimizing the current flow at the time of opening will improve this value.

什么是负载信号?

Reed switches whether they are used in sensors or relays all will be asked to switch some load.  Generally there are two aspects to this load.

  1. Its steady state load
  2. Is the actual switching taking place during the first 50 nanoseconds.  This is also called the signature of the load.

This signature takes into consideration not only the steady state load but also any transient voltages or current that may be present during the first 50 nanoseconds.  These transients may be from stray capacitance, inductance in the line and/or common mode voltages.  From a reed switch designer standpoint, the signature is all there is.  The most important time during the switching of a load is that first 50 nanoseconds.  That is when all the damage to the contacts with occur if you are switching the contacts ‘hot’.  If a customer is having a problem with early failures, this is the first place to look.  Equally important and not to be overlooked is what voltage and current is actually being broken when the contacts open.  Any healthy voltage and/or current present will chew up the contacts rapidly leading to sticking reed contacts.

我怎么选择干簧管呢?

There are several key factors:

  1. You need to have an idea of the required load.  What voltage and current is being switched at the time of closure for the first 50 nanoseconds?
  2. How many operations will be required during the life of the product?
  3. What are the size requirements?  How much room is needed?
  4. How will the product be mounted? Surface mount, thru hole, etc.
  5. For long life and low levels, use a ruthenium or an iridium sputtered/plated switch.
  6. For switching applications from 50 Volts to 200 volts use the Philips/Coto/Comus sputtered ruthenium switch.
  7. For switching currents 25 ma to 1 amp, the KOFU thickly plated rhodium is good along with our KSK-1A35.
  8. For higher voltages above 200 volts  up to 4000 volts at relatively low current use the  OKI ORD2210V.
  9. For voltages above 1000 volts up to 10,000 volts with higher currents use the Hermetic vacuum switches.  This represents a start.  One could write a book on this subject.  Best to find out the exact customer load and run a life test with a few or several reed switches to make the final determination.